The concrete walls of these storage tanks were found to have cracked quite extensively and, as part of a refurbishment program, Corroless Eastern carried out some over-banding and some resin injection works to seal existing cracks and joints in the tanks.
AQURON 7000 was then applied to waterproof the concrete and protect the rebar, reducing any future degradation in these tank structures.